18-step bar for displaying gas concentration; additional maximum leakage display
Quick reaction time with built-in pump
Flexible gooseneck sensor for checking hard-to-reach pipes and places
Rechargeable batteries for longer performance
General technical data | |
---|---|
Operating humidity |
20 to 80 %RH |
Weight |
348 g |
Reaction time |
t90 < 2 s |
Dimensions |
190 x 57 x 42 mm (without sensors) |
Operating temperature |
-5 to +50 °C |
Heat up time |
60 s |
Battery type |
NiMH battery |
Battery life |
6 h |
Display type |
0 |
Storage temperature |
-25 to +60 °C |
Methane (CH?) | |
---|---|
Measuring range |
10 ppm to 4.0 Vol.% |
Lower response threshold |
10 ppm |
1st alarm limit |
200 ppm |
2nd alarm limit |
10000 ppm |
Propane (C?H?) | |
---|---|
Measuring range |
10 ppm to 1.9 Vol.% |
Lower response threshold |
10 ppm |
1st alarm limit |
100 ppm |
2nd alarm limit |
5000 ppm |
Leak detection H? | |
---|---|
Measuring range |
10 ppm to 4.0 Vol.% |
Lower response threshold |
10 ppm |
1st alarm limit |
200 ppm |
2nd alarm limit |
10000 ppm |